Please contact Drivven for pricing and additional information
Tracks angular position of engine crankshaft having a trigger pattern of N evenly spaced teeth with a single additional “Plus1” tooth between two evenly spaced teeth.
Tracks 360 degrees (2-stroke) or 720 degrees (4-stroke) with optional camshaft reference input
Parameterized angular resolution by powers of 2
Maximum engine speed limited only by clock input frequency
Achieves engine sync on first detected Plus1 tooth after a specified crank tooth count
Capable of adjusting engine position by 360 degrees upon request
Remains synchronized at loss of cam signal
Interrupt-style flags for no cam signal, missed crank tooth, and missed Plus1 tooth (in case of false or missing crank teeth)
Provides the following output information to CPU and supervised cores:
Current position
Crank tooth period (Actual)
Crank tooth period (Plus1-tooth-compensated)
Crank tooth count
Current tooth period timer value
Crank tooth one-shot
Engine stalled signal
Sync stopped signal
Error flags
Notes:
Drivven is a member of the Xilinx-sponsored SignOnce IP Common License Consortium. Please refer to these standard license agreement documents for details.
SignOnce IP Project License Form
SignOnce IP Site License Form
Project licenses allow the netlist or source to be used for a single project.
Site licenses allow the netlist or source to be used for unlimited number of projects.
Upon request, Drivven will provide an evaluation netlist which contains a 5-minute time-bomb.
ModelSim test fixtures are available for simulation evaluation.